Skip to main content

DPF Mechanical 2026 R1

fft_multi_harmonic_minmax class

Last update: 18.06.2026

Namespace: Ans.DataProcessing.operators.math

Summary

Evaluate min max fields on multi harmonic solution. min and max fields are calculated based on evaluating a fourier series sum wrt rpms and using the gradient method for adaptive time steping

available inputs: fields_container (FieldsContainer), rpm_scoping (Scoping) (optional), fs_ratio (Int32) (optional), num_subdivisions (Int32) (optional), max_num_subdivisions (Int32) (optional), num_cycles (Int32) (optional), use_harmonic_zero (bool) (optional), calculate_time_series (bool) (optional), substeps_selector (IList int, System.Collections.IEnumerable) (optional)

available outputs: field_min (FieldsContainer), field_max (FieldsContainer), all_fields (FieldsContainer)

Example

op = fft_multi_harmonic_minmax()

op = fft_multi_harmonic_minmax(fields_container=my_fields_container,rpm_scoping=my_rpm_scoping,fs_ratio=my_fs_ratio,num_subdivisions=my_num_subdivisions,max_num_subdivisions=my_max_num_subdivisions,num_cycles=my_num_cycles,use_harmonic_zero=my_use_harmonic_zero,calculate_time_series=my_calculate_time_series,substeps_selector=my_substeps_selector)

Class Information

Property Value
Namespace Ans.DataProcessing.operators.math
Assembly Ans_Dpf_Math_dll_cs
Base Class Ans.DataProcessing.internal_objects.BaseOperator

Inputs

fields_container

Type: LinkableInput

rpm_scoping

rpm scoping, by default the fourier series sum is evaluated using all the rpms

Type: LinkableInput

fs_ratio

field or fields container with only one field is expected

Type: LinkableInput

num_subdivisions

connect number subdivisions, used for uniform discretization

Type: LinkableInput

max_num_subdivisions

connect max number subdivisions, used to avoid huge number of sudivisions

Type: LinkableInput

num_cycles

Number of cycle of the periodic signal (default is 2)

Type: LinkableInput

use_harmonic_zero

use harmonic zero for first rpm (default is false)

Type: LinkableInput

calculate_time_series

calculates time series output (output pin 2), setting it to false enhance performance if only min/max are required (default is true)

Type: LinkableInput

substeps_selector

substeps to evaluate (frequencies), by default the operator is evaluated using all the available steps

Type: LinkableInput

Outputs

field_min

Type: LinkableOutput

field_max

Type: LinkableOutput

all_fields

Type: LinkableOutput

Constructors

Constructor

fft_multi_harmonic_minmax()

Constructor

fft_multi_harmonic_minmax(fields_container, rpm_scoping, fs_ratio, num_subdivisions, max_num_subdivisions, num_cycles, use_harmonic_zero, calculate_time_series, substeps_selector, config)

Parameters:

  • fields_container (object)
  • rpm_scoping (object)
  • fs_ratio (object)
  • num_subdivisions (object)
  • max_num_subdivisions (object)
  • num_cycles (object)
  • use_harmonic_zero (object)
  • calculate_time_series (object)
  • substeps_selector (object)
  • config (OperatorConfig)

Constructor

fft_multi_harmonic_minmax(config)

Parameters:

  • config (OperatorConfig)

Methods

Properties

inputs

Type: InputSpec

# Get or set the property
value = obj.inputs
obj.inputs = new_value

outputs

Type: OutputSpec

# Get or set the property
value = obj.outputs
obj.outputs = new_value

defaultConfig

Type: Config

# Get the property (read-only)
value = obj.defaultConfig