MaximumPrincipalThermalStrain
Last update: 14.01.2025
MaximumPrincipalThermalStrain
class Ansys.ACT.Automation.Mechanical.Results.StrainResults.MaximumPrincipalThermalStrain
Bases: object
Defines a MaximumPrincipalThermalStrain.
Overview
Methods
Name | Description |
---|---|
Activate |
Activate the current object. |
AddAlert |
Creates a new Alert |
AddComment |
Creates a new child Comment. |
AddConvergence |
Creates a new Convergence |
AddFigure |
Creates a new child Figure. |
AddImage |
Creates a new child Image. |
ClearGeneratedData |
Run the ClearGeneratedData action. |
CopyTo |
Copies all visible properties from this object to another. |
CreateParameter |
CreateParameter method. |
CreateResultsAtAllSets |
Creates results at all sets for results under a solution. |
Delete |
Run the Delete action. |
Duplicate |
Creates a copy of the current DataModelObject. |
DuplicateWithoutResults |
Run the DuplicateWithoutResults action. |
EvaluateAllResults |
Run the EvaluateAllResults action. |
ExportAnimation |
Run the ExportAnimation action. |
ExportToTextFile |
Run the ExportToTextFile action. |
FetchRemoteResults |
Run the FetchRemoteResult action. |
GetChildren |
Gets the list of children, filtered by type. |
GetParameter |
Gets the parameter corresponding to the given property. |
GroupAllSimilarChildren |
Run the GroupAllSimilarChildren action. |
GroupSimilarObjects |
Run the GroupSimilarObjects action. |
PromoteToNamedSelection |
Run the PromoteToNamedSelection action. |
PropertyByAPIName |
Get a property by its API name. |
PropertyByName |
Get a property by its unique name. |
RemoveParameter |
Removes the parameter from the parameter set corresponding to the given property. |
RenameBasedOnDefinition |
Run the RenameBasedOnDefinition action. |
Properties
Name | Description |
---|---|
Amplitude |
Gets or sets the Amplitude. |
Average |
Gets the Average. |
AverageAcrossBodies |
Gets or sets the AverageAcrossBodies. |
By |
Gets or sets the By. |
CalculateTimeHistory |
Gets or sets the CalculateTimeHistory. |
Children |
Gets the list of children. |
CombinationNumber |
Gets or sets the Combination Number for a Solution Combination result. |
Comments |
Gets the list of associated comments. |
CoordinateSystem |
Gets or sets the Coordinate System. |
CrackFrontNumber |
Gets or sets the CrackFrontNumber. |
CyclicMode |
Gets or sets the CyclicMode. |
DataModelObjectCategory |
Gets the current DataModelObject’s category. |
DisplayOption |
Gets or sets the DisplayOption. |
DisplayTime |
Gets or sets the DisplayTime. |
DpfEvaluation |
Gets or sets the DpfEvaluation. |
EnvironmentSelection |
Gets or sets the EnvironmentSelection. |
Figures |
Gets the list of associated figures. |
Frequency |
Gets or sets the Frequency. |
GlobalIDs |
Gets or sets the GlobalIDs. |
GraphControlsXAxis |
Gets or sets the GraphControlsXAxis. |
HarmonicIndex |
Gets or sets the HarmonicIndex. |
Identifier |
Gets or sets the Identifier. |
Images |
Gets the list of associated images. |
InternalObject |
Gets the internal object. For advanced usage only. |
IsSolved |
Gets the IsSolved. |
ItemType |
Gets or sets the ItemType. |
IterationNumber |
Gets the IterationNumber. |
IterationStep |
Gets or sets the IterationStep. |
LoadMultiplier |
Gets the LoadMultiplier. |
LoadStep |
Gets the LoadStep. |
LoadStepForMaximumOfMaximumValues |
Get the Load Step for the maximum of maximum values. |
LoadStepForMaximumOfMinimumValues |
Get the Load Step for the maximum of minimum values. |
LoadStepForMinimumOfMaximumValues |
Get the Load Step for the minimum of maximum values. |
LoadStepForMinimumOfMinimumValues |
Get the Load Step for the minimum of minimum values. |
LoadStepNumber |
Gets or sets the LoadStepNumber. |
Location |
Gets or sets the Location. |
Maximum |
Gets the Maximum. |
MaximumOccursOn |
Gets the MaximumOccursOn. |
MaximumOfMaximumOverTime |
Gets the MaximumOfMaximumOverTime. |
MaximumOfMinimumOverTime |
Gets the MaximumOfMinimumOverTime. |
Minimum |
Gets the Minimum. |
MinimumOccursOn |
Gets the MinimumOccursOn. |
MinimumOfMaximumOverTime |
Gets the MinimumOfMaximumOverTime. |
MinimumOfMinimumOverTime |
Gets the MinimumOfMinimumOverTime. |
Mode |
Gets or sets the Mode. |
NamedSelections |
Gets or sets the NamedSelections. |
Path |
Path property. |
PhaseIncrement |
Gets or sets the PhaseIncrement. |
Plies |
Plies property. |
PlotData |
Gets the result table. |
Ply |
Gets or sets the Ply selection. |
Position |
Gets or sets the Position. |
Properties |
Gets the list of properties for this object. |
RPMSelection |
Gets or sets the RPM Selection value at which the results are evaluated. |
ReportedFrequency |
Gets the ReportedFrequency. |
ScopingMethod |
Gets or sets the ScopingMethod. |
SetNumber |
Gets or sets the Set Number. |
SolutionCombinationDriver |
Gets or sets the SolutionCombinationDriver. |
SolverComponentIDs |
Gets or sets the SolverComponentIDs. |
StressStrainType |
Gets or sets the StressStrainType. |
SubScopeBy |
Gets or sets the SubScopeBy. |
Substep |
Gets the Substep. |
Suppressed |
Gets or sets the Suppressed. |
Surface |
Surface property. |
SurfaceCoating |
SurfaceCoating property. |
SweepingPhase |
Gets or sets the SweepingPhase. |
Time |
Gets the Time. |
TimeForMaximumOfMaximumValues |
Get the Time for the maximum of maximum values. |
TimeForMaximumOfMinimumValues |
Get the Time for the maximum of minimum values. |
TimeForMinimumOfMaximumValues |
Get the Time for the minimum of maximum values. |
TimeForMinimumOfMinimumValues |
Get the Time for the minimum of minimum values. |
Total |
Gets the Total. |
VisibleProperties |
Gets the list of properties that are visible for this object. |
Property detail
property MaximumPrincipalThermalStrain.Amplitude : bool | None
Gets or sets the Amplitude.
property MaximumPrincipalThermalStrain.Average : Ansys.Core.Units.Quantity | None
Gets the Average.
property MaximumPrincipalThermalStrain.AverageAcrossBodies : bool | None
Gets or sets the AverageAcrossBodies.
property MaximumPrincipalThermalStrain.By : Ansys.Mechanical.DataModel.Enums.SetDriverStyle | None
Gets or sets the By.
property MaximumPrincipalThermalStrain.CalculateTimeHistory : bool | None
Gets or sets the CalculateTimeHistory.
property MaximumPrincipalThermalStrain.Children : List[Ansys.Mechanical.DataModel.Interfaces.IDataModelObject] | None
Gets the list of children.
property MaximumPrincipalThermalStrain.CombinationNumber : int | None
Gets or sets the Combination Number for a Solution Combination result.
property MaximumPrincipalThermalStrain.Comments : Iterable[Ansys.ACT.Automation.Mechanical.Comment] | None
Gets the list of associated comments.
property MaximumPrincipalThermalStrain.CoordinateSystem : Ansys.ACT.Automation.Mechanical.CoordinateSystem | None
Gets or sets the Coordinate System. Accepts/Returns None for Solution Coordinate System in the general case (if applicable). Accepts/Returns None for Fiber Coordinate System for a result that is sub scoped by ply.
property MaximumPrincipalThermalStrain.CrackFrontNumber : int | None
Gets or sets the CrackFrontNumber.
property MaximumPrincipalThermalStrain.CyclicMode : int | None
Gets or sets the CyclicMode.
property MaximumPrincipalThermalStrain.DataModelObjectCategory : Ansys.Mechanical.DataModel.Enums.DataModelObjectCategory | None
Gets the current DataModelObject’s category.
property MaximumPrincipalThermalStrain.DisplayOption : Ansys.Mechanical.DataModel.Enums.ResultAveragingType | None
Gets or sets the DisplayOption.
property MaximumPrincipalThermalStrain.DisplayTime : Ansys.Core.Units.Quantity | None
Gets or sets the DisplayTime.
property MaximumPrincipalThermalStrain.DpfEvaluation : Ansys.Mechanical.DataModel.Enums.DpfEvaluationType | None
Gets or sets the DpfEvaluation.
property MaximumPrincipalThermalStrain.EnvironmentSelection : Ansys.ACT.Automation.Mechanical.Analysis | None
Gets or sets the EnvironmentSelection.
property MaximumPrincipalThermalStrain.Figures : Iterable[Ansys.ACT.Automation.Mechanical.Figure] | None
Gets the list of associated figures.
property MaximumPrincipalThermalStrain.Frequency : Ansys.Core.Units.Quantity | None
Gets or sets the Frequency.
property MaximumPrincipalThermalStrain.GlobalIDs : str | None
Gets or sets the GlobalIDs.
property MaximumPrincipalThermalStrain.GraphControlsXAxis : Ansys.Mechanical.DataModel.Enums.GraphControlsXAxis | None
Gets or sets the GraphControlsXAxis.
property MaximumPrincipalThermalStrain.HarmonicIndex : int | None
Gets or sets the HarmonicIndex.
property MaximumPrincipalThermalStrain.Identifier : str | None
Gets or sets the Identifier.
property MaximumPrincipalThermalStrain.Images : Iterable[Ansys.ACT.Automation.Mechanical.Image] | None
Gets the list of associated images.
property MaximumPrincipalThermalStrain.InternalObject : Ansys.Common.Interop.DSObjectsAuto.IDSResultAuto | None
Gets the internal object. For advanced usage only.
property MaximumPrincipalThermalStrain.IsSolved : bool | None
Gets the IsSolved.
property MaximumPrincipalThermalStrain.ItemType : Ansys.Mechanical.DataModel.Enums.ResultFileItemType | None
Gets or sets the ItemType.
property MaximumPrincipalThermalStrain.IterationNumber : int | None
Gets the IterationNumber.
property MaximumPrincipalThermalStrain.IterationStep : int | None
Gets or sets the IterationStep.
property MaximumPrincipalThermalStrain.LoadMultiplier : float | None
Gets the LoadMultiplier.
property MaximumPrincipalThermalStrain.LoadStep : int | None
Gets the LoadStep.
property MaximumPrincipalThermalStrain.LoadStepForMaximumOfMaximumValues : int | None
Get the Load Step for the maximum of maximum values.
property MaximumPrincipalThermalStrain.LoadStepForMaximumOfMinimumValues : int | None
Get the Load Step for the maximum of minimum values.
property MaximumPrincipalThermalStrain.LoadStepForMinimumOfMaximumValues : int | None
Get the Load Step for the minimum of maximum values.
property MaximumPrincipalThermalStrain.LoadStepForMinimumOfMinimumValues : int | None
Get the Load Step for the minimum of minimum values.
property MaximumPrincipalThermalStrain.LoadStepNumber : int | None
Gets or sets the LoadStepNumber.
property MaximumPrincipalThermalStrain.Location : Ansys.ACT.Interfaces.Common.ISelectionInfo | None
Gets or sets the Location.
property MaximumPrincipalThermalStrain.Maximum : Ansys.Core.Units.Quantity | None
Gets the Maximum.
property MaximumPrincipalThermalStrain.MaximumOccursOn : str | None
Gets the MaximumOccursOn.
property MaximumPrincipalThermalStrain.MaximumOfMaximumOverTime : Ansys.Core.Units.Quantity | None
Gets the MaximumOfMaximumOverTime.
property MaximumPrincipalThermalStrain.MaximumOfMinimumOverTime : Ansys.Core.Units.Quantity | None
Gets the MaximumOfMinimumOverTime.
property MaximumPrincipalThermalStrain.Minimum : Ansys.Core.Units.Quantity | None
Gets the Minimum.
property MaximumPrincipalThermalStrain.MinimumOccursOn : str | None
Gets the MinimumOccursOn.
property MaximumPrincipalThermalStrain.MinimumOfMaximumOverTime : Ansys.Core.Units.Quantity | None
Gets the MinimumOfMaximumOverTime.
property MaximumPrincipalThermalStrain.MinimumOfMinimumOverTime : Ansys.Core.Units.Quantity | None
Gets the MinimumOfMinimumOverTime.
property MaximumPrincipalThermalStrain.Mode : int | None
Gets or sets the Mode.
property MaximumPrincipalThermalStrain.NamedSelections : Iterable[Ansys.Mechanical.DataModel.Interfaces.IDataModelObject] | None
Gets or sets the NamedSelections.
property MaximumPrincipalThermalStrain.Path : Ansys.ACT.Automation.Mechanical.Path | None
Path property.
property MaximumPrincipalThermalStrain.PhaseIncrement : Ansys.Core.Units.Quantity | None
Gets or sets the PhaseIncrement.
property MaximumPrincipalThermalStrain.Plies : Iterable[Ansys.ACT.Automation.Mechanical.ImportedPliesCollection] | None
Plies property.
property MaximumPrincipalThermalStrain.PlotData : Ansys.Mechanical.DataModel.Results.ResultDataTable | None
Gets the result table.
property MaximumPrincipalThermalStrain.Ply : Iterable[Ansys.ACT.Automation.Mechanical.AnalysisPly] | None
Gets or sets the Ply selection.
property MaximumPrincipalThermalStrain.Position : Ansys.Mechanical.DataModel.Enums.ShellFaceType | None
Gets or sets the Position.
property MaximumPrincipalThermalStrain.Properties : tuple[Ansys.ACT.Automation.Mechanical.Property] | None
Gets the list of properties for this object.
property MaximumPrincipalThermalStrain.RPMSelection : Ansys.Core.Units.Quantity | None
Gets or sets the RPM Selection value at which the results are evaluated.
property MaximumPrincipalThermalStrain.ReportedFrequency : Ansys.Core.Units.Quantity | None
Gets the ReportedFrequency.
property MaximumPrincipalThermalStrain.ScopingMethod : Ansys.Mechanical.DataModel.Enums.GeometryDefineByType | None
Gets or sets the ScopingMethod.
property MaximumPrincipalThermalStrain.SetNumber : int | None
Gets or sets the Set Number.
property MaximumPrincipalThermalStrain.SolutionCombinationDriver : Ansys.Mechanical.DataModel.Enums.SolutionCombinationDriverStyle | None
Gets or sets the SolutionCombinationDriver.
property MaximumPrincipalThermalStrain.SolverComponentIDs : str | None
Gets or sets the SolverComponentIDs.
property MaximumPrincipalThermalStrain.StressStrainType : Ansys.Mechanical.DataModel.Enums.StressStrainType | None
Gets or sets the StressStrainType.
property MaximumPrincipalThermalStrain.SubScopeBy : Ansys.Mechanical.DataModel.Enums.SubScopingDefineByType | None
Gets or sets the SubScopeBy.
property MaximumPrincipalThermalStrain.Substep : int | None
Gets the Substep.
property MaximumPrincipalThermalStrain.Suppressed : bool | None
Gets or sets the Suppressed.
property MaximumPrincipalThermalStrain.Surface : Ansys.ACT.Automation.Mechanical.Surface | None
Surface property.
property MaximumPrincipalThermalStrain.SurfaceCoating : Ansys.ACT.Automation.Mechanical.SurfaceCoating | None
SurfaceCoating property.
property MaximumPrincipalThermalStrain.SweepingPhase : Ansys.Core.Units.Quantity | None
Gets or sets the SweepingPhase.
property MaximumPrincipalThermalStrain.Time : Ansys.Core.Units.Quantity | None
Gets the Time.
property MaximumPrincipalThermalStrain.TimeForMaximumOfMaximumValues : Ansys.Core.Units.Quantity | None
Get the Time for the maximum of maximum values.
property MaximumPrincipalThermalStrain.TimeForMaximumOfMinimumValues : Ansys.Core.Units.Quantity | None
Get the Time for the maximum of minimum values.
property MaximumPrincipalThermalStrain.TimeForMinimumOfMaximumValues : Ansys.Core.Units.Quantity | None
Get the Time for the minimum of maximum values.
property MaximumPrincipalThermalStrain.TimeForMinimumOfMinimumValues : Ansys.Core.Units.Quantity | None
Get the Time for the minimum of minimum values.
property MaximumPrincipalThermalStrain.Total : Ansys.Core.Units.Quantity | None
Gets the Total.
property MaximumPrincipalThermalStrain.VisibleProperties : tuple[Ansys.ACT.Automation.Mechanical.Property] | None
Gets the list of properties that are visible for this object.
Method detail
MaximumPrincipalThermalStrain.Activate()
Activate the current object.
MaximumPrincipalThermalStrain.AddAlert()
Creates a new Alert
MaximumPrincipalThermalStrain.AddComment()
Creates a new child Comment.
MaximumPrincipalThermalStrain.AddConvergence()
Creates a new Convergence
MaximumPrincipalThermalStrain.AddFigure()
Creates a new child Figure.
MaximumPrincipalThermalStrain.AddImage(filePath: str)
Creates a new child Image.
If a filePath is provided, the image will be loaded from that file,
if not, the image will be a screen capture of the Geometry window.
MaximumPrincipalThermalStrain.ClearGeneratedData()
Run the ClearGeneratedData action.
MaximumPrincipalThermalStrain.CopyTo(other: Ansys.ACT.Automation.Mechanical.DataModelObject)
Copies all visible properties from this object to another.
MaximumPrincipalThermalStrain.CreateParameter(propName: str)
CreateParameter method.
MaximumPrincipalThermalStrain.CreateResultsAtAllSets()
Creates results at all sets for results under a solution.
MaximumPrincipalThermalStrain.Delete()
Run the Delete action.
MaximumPrincipalThermalStrain.Duplicate()
Creates a copy of the current DataModelObject.
MaximumPrincipalThermalStrain.DuplicateWithoutResults()
Run the DuplicateWithoutResults action.
MaximumPrincipalThermalStrain.EvaluateAllResults()
Run the EvaluateAllResults action.
MaximumPrincipalThermalStrain.ExportAnimation(filePath: str, format: Ansys.Mechanical.DataModel.Enums.GraphicsAnimationExportFormat, settings: Ansys.Mechanical.Graphics.AnimationExportSettings)
Run the ExportAnimation action.
MaximumPrincipalThermalStrain.ExportToTextFile(filePath: str)
Run the ExportToTextFile action.
MaximumPrincipalThermalStrain.FetchRemoteResults()
Run the FetchRemoteResult action.
MaximumPrincipalThermalStrain.GetChildren(recurses: bool, children: List[ChildrenType])
Gets the list of children, filtered by type.
MaximumPrincipalThermalStrain.GetParameter(propName: str)
Gets the parameter corresponding to the given property.
MaximumPrincipalThermalStrain.GroupAllSimilarChildren()
Run the GroupAllSimilarChildren action.
MaximumPrincipalThermalStrain.GroupSimilarObjects()
Run the GroupSimilarObjects action.
MaximumPrincipalThermalStrain.PromoteToNamedSelection()
Run the PromoteToNamedSelection action.
MaximumPrincipalThermalStrain.PropertyByAPIName(name: str)
Get a property by its API name.
If multiple properties have the same API Name, only the first property with that name will be returned.
MaximumPrincipalThermalStrain.PropertyByName(name: str)
Get a property by its unique name.
MaximumPrincipalThermalStrain.RemoveParameter(propName: str)
Removes the parameter from the parameter set corresponding to the given property.
MaximumPrincipalThermalStrain.RenameBasedOnDefinition()
Run the RenameBasedOnDefinition action.